Onset HOBO Data Loggers U30-NRC-VIA-05-S100-000

Onset HOBO Data Loggers U30-NRC-VIA-05-S100-000

0 out of 5

$278.00

SKU: NSKU1069 Category: Tags: , , ,
View cart

Description

  • 2-Channel Analog Sensor Port
  • 5 Smart Sensor Inputs
  • All electronics are housed within a rugged double-weatherproof, tamper-proof enclosure
  • Setup is quick and easy with plug-and-play sensors
  • Fast data offload via USB
  • Optional analog inputs with sensor excitation
  • Includes relay that can be activated on user-defined alarm conditions
  • Normal operating range: -20°C to 40°C (-4°F to 104°F)
  • Extended operating range: -40 to 60°C (-40 to 140°F) see Rechargeable Battery service Life for impact of operations in Extended Operating Range.
  • Sensor Inputs: 5 standard, option to expand to 10
  • Smart Sensor Compatibility: Compatible with most Onset smart sensors, except for the S-BPA, S-TMA and S-THA
  • Data Channels: Maximum of 15 (some sensors use more than one data channel)
  • Alarm Output Relay: Can be configured to be activated, deactivated or pulsed on user-defined sensor alarms. The relay can be configured as normally open or normally closed, and is rated for 30 V and 1 amp max.
  • Expansion Slot: One expansion slot is available for factory-installed expansion port.
  • Local Communication: Full Speed USB via USB mini-B connector
  • Size: 17.8 H x 11.7 D x 19.3 W cm (7.0 H x 4 .6 D x 7.6 W inches)
  • Weight: 2 kg (4 lbs 10 oz)
  • Materials: Outer Enclosure: ABS blend with stainless steel hinge pins and bronze inserts Inner Enclosure: Polycarbonate with bronze inserts U-Bolts: Steel with zinc dichromate finish Gaskets: Silicone rubber Cable entry channel: EPDM rubber Cable entry bars: Aluminum with ABS plastic thumb screws
  • Data Storage Memory: Nonvolatile flash data storage, 512K bytes local storage
  • Memory Modes: Stop when full, wrap around when full
  • Operational Indicators: Up to six (depending upon options) status lights provide basic diagnostics
  • Logging Interval: 1 second to 18 hours, user-specified interval
  • Battery Type: 4 Volt, 4.5 AHr or 10 AHr, Rechargeable sealed lead-acid
  • Rechargeable Battery Service Life: Typical 3–5 years depending upon conditions of use. Operation within the extended operating range (but outside the normal range) will reduce battery service life.
  • Time Accuracy: 0 to 2 seconds for the first data point and ±5 seconds per week at 25°C (77°F)
  • Environmental Rating: Weatherproof enclosure, tested to NEMA 6. (Requires proper installation of cable channel system)
  • Mounting: 3.8 cm (1.5 inch) mast or wall mount
  • Enclosure Access: Hinged door secured by two latches with eyelets for securing with user-supplied padlocks
  • Sensor Network Cable Length: 100 m (328 ft) maximum
  • External Power: External power is required. The system optionally accepts the following Onset solar panels: •SOLAR-1.2W •SOLAR-3W •SOLAR-6W
  • Alternatively it accepts an AC power adapter: •AC-U30
  • Optional Analog Sensor Port Specifications
  • Input Channels: Two, single-ended
  • Field Wiring: Two- or three-wire via screw terminals on detachable connector, 16–24 AWG. Replacement detachable connectors: Part of spares kit, Part No. A-FS-CVIA-7P-1
  • Input Range: User-configurable: 0–20 mA DC, 0-2.5 VDC, 0-5 VDC, 0-10 VDC, or 0–20 VDC
  • Minimum / Maximum Input Voltage: 0 / 24 VDC
  • Minimum / Maximum Input Current: 0 / 24 mA DC
  • Minimum Current Source Impedance: &gt, 20 KΩ
  • Accuracy: ± 0.25% of FSR from 50mV to FSV
  • ADC Resolution 12 bits
  • Excitation Power: Switched 12 VDC, up to 50 mA, user-selectable warm-up from 5msec to 2 minutes