Gossen Metrawatt PROFITEST MTECH+

Gossen Metrawatt PROFITEST MTECH+

0 out of 5

$1,351.00

View cart

Description

A broad-range measuring device allows for use of the test instrument in all alternating and 3-phase electrical systems with voltages from 65 to 500 V and frequencies of 15.4 to 420 Hz.

  • Loop and line impedance measurement
  • Measurement of insulation resistance using nominal voltage, with variable or rising test voltage
  • Low-resistance measurement
  • Earth resistance measurement
  • Standing-Surface Insulation MeasurementBLUETOOTH Interface Logo
  • Universal connector system
  • Standard-compliant Testing of Electric Vehicle Charging Stations in accordance with IEC 60364-6 and IEC 61851

>

Testing of residual current devices (RCCBs)

  • Measurement of contact voltage without tripping the RCCB
  • Contact voltage is measured with reference to nominal residual current using 1/3 of the nominal residual current value
  • Tripping test with nominal residual current, tripping time measurement

>

Special testing for systems and RCCBs

  • Testing of equipment and RCCBs with rising residual current including indication of tripping current and contact voltage at the moment the RCCB is tripped
  • Testing of RCCBs with: 1/2x, 1x, 2x, 5x IΔN
  • Testing of RCCBs which are suitable for pulsating residual direct current, testing is conducted with positive or negative half-waves
  • Testing of RCCBs with adjustable residual current for determining contact voltage

>

Testing for special RCDs

  • Selective S, SRCDs, PRCDs (Schukomat, Sidos and others), types G/R, AC, A, F, Type B, B , EV

>

Special features of the PROFITEST MASTER family

  • EASY transfer stands for direct incorporation of the Profitest Master into DDS-CAD planning software
  • Display of approved fuse types for electrical systems
  • Programable test sequences
  • Energy meter start-up testing
  • Calculation of cable lengths for common copper wire cross-sections
  • Measurement of biasing, leakage and circulating current up to 1 A, as well as working current up to 150 A with the WZ12C current sensor clamp as an accessory
  • Phase sequence measurement (including highest line-to-line voltage)
  • Measurement of contact voltage without tripping the RCCB
  • Contact voltage is measured with reference to nominal residual current using 1/3 of the nominal residual current value
  • Tripping test with nominal residual current, tripping time measurement

>

Each Unit Includes

  • 1 Test instrument
  • 1 Earthing contact plug insert (country-specific)
  • 1 2-pole measuring adapter and 1 cable for expansion into a 3-pole adapter (PRO-A3-II)
  • 2 Alligator clips
  • 1 Shoulder strap
  • 1 Set of rechargeable batteries (Z502H)
  • 1 Battery charger Z502R
  • 1 Condensed operating instructions
  • 1 Supplement Safety Information
  • 1 DAkkS calibration certificate
  • 1 USB cable