Overview

The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mind. The 726 measures and sources almost all process parameters and can calibrate almost anything. The 726 will also interpret results without the help of a calculator and store measurement data for later analysis.

Need an intrinsically safe rating in your calibrator? Consider the Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator.

Want documenting and HART communication built into your calibrator? Consider the Fluke 754 Documenting Process Calibrator with HART.

  • Save over $205 with the Fluke 726 VIP Kit.
    • Limited Time Offer.
    • FREE T/C Lead Set (22171T)
    • FREE Toolpak Hanger (TPAK80-4)
    • FREE C-101 Carrying Case
    • FREE Leatherman Tool (80141TL)
    • FREE 32 Pack of Green Calibration Labels

    >

>

See the 726 VIP Kit now!

  • More precise measurement and calibration source performance, accuracies of 0.01%.
  • Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis
  • Two separate channels, measure, source and view process signals simultaneously
  • Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters
  • Measure or source pressure using any of 29 Fluke 700Pxx Pressure Modules (Pressure pump required)
  • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Integrated pressure switch test allows you to capture the set, reset and deadband of a switch
  • Transmitter error% calculation, interpret calibration results without a calculator
  • Perform fast linearity tests with auto step and auto ramp features
  • Power transmitters during test using 24 V loop supply and simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing
  • HART mode inserts 250 ohm resistor in mA measure and source for compatibility with
  • HART instrumentation
  • Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement.
  • New voltage input protection design for improved reliability
  • Three-year warranty

>

Each Unit Includes

  • TL75 test leads
  • AC72 test clips
  • CD user’s manuals (English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish, Finnish, Portuguese, Korean, Chinese, Japanese)

    Overview

    The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mind. The 726 measures and sources almost all process parameters and can calibrate almost anything. The 726 will also interpret results without the help of a calculator and store measurement data for later analysis.

    Need an intrinsically safe rating in your calibrator? Consider the Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator.

    Want documenting and HART communication built into your calibrator? Consider the Fluke 754 Documenting Process Calibrator with HART.

    • Save over $205 with the Fluke 726 VIP Kit.
      • Limited Time Offer.
      • FREE T/C Lead Set (22171T)
      • FREE Toolpak Hanger (TPAK80-4)
      • FREE C-101 Carrying Case
      • FREE Leatherman Tool (80141TL)
      • FREE 32 Pack of Green Calibration Labels

      >

    >

    See the 726 VIP Kit now!

    • More precise measurement and calibration source performance, accuracies of 0.01%.
    • Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis
    • Two separate channels, measure, source and view process signals simultaneously
    • Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
    • Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters
    • Measure or source pressure using any of 29 Fluke 700Pxx Pressure Modules (Pressure pump required)
    • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
    • Integrated pressure switch test allows you to capture the set, reset and deadband of a switch
    • Transmitter error% calculation, interpret calibration results without a calculator
    • Perform fast linearity tests with auto step and auto ramp features
    • Power transmitters during test using 24 V loop supply and simultaneous mA measurement
    • Store frequently-used test setups for later use
    • Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing
    • HART mode inserts 250 ohm resistor in mA measure and source for compatibility with
    • HART instrumentation
    • Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement.
    • New voltage input protection design for improved reliability
    • Three-year warranty

    >

    Each Unit Includes

    • TL75 test leads
    • AC72 test clips
    • CD user’s manuals (English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish, Finnish, Portuguese, Korean, Chinese, Japanese)

    >

    Measurement Accuracy
    Voltage DC 30.000 V 0.01% 2 mV (upper display)
    20.000 V 0.01% 2 mV (lower display)
    90.00 mV 0.01% 10 μV
    -10.00 mV to 75.00 mV 0.025% 1 count (via TC connector)
    Current DC 24.000 mA 0.01% 2 mA
    Resistance 0.0 to 4000.0 Ω ± 0.015%
    Frequency 2.0 to 1000.0 CPM 0.05% 0.1 cpm
    1.0 to 1000.0 Hz 0.05% 0.1 Hz
    1.00 to 15.00 kHz 0.05% 0.01 kHz
    Sensitivity 1 V peak-to-peak-minimum
    Pressure Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
    Source Accuracy
    Voltage DC 100.00 mV 0.01% 10 μV
    20.000 V 0.01% 2 mV
    -10.00 mV to 75.00 mV 0.025% 1 count (via TC connector)
    Current DC 24.000 mA (Source) 0.01% 2 μA
    24.000 mA (Simulate) 0.01% 2 μA
    Resistance Range, accuracy (percent of reading floor) and excitation current 5 to 400 Ω, 0.015% 0.1 Ω, 0.1 to 0.5 mA
    5 to 400 Ω, 0.015% 0.05 Ω, 0.5 to 3 mA
    400 to 1500 Ω, 0.015% 0.5 Ω, 0.05 to 0.8 mA
    1500 to 4000 Ω, 0.015% 0.5 Ω, 0.05 to 0.4 mA
    Frequency 2.0 to 1000.0 CPM 0.05%
    1.0 to 1000.0 Hz 0.05%
    1.0 to 10.0 kHz 0.25%
    10.0 to 15.0 kHz 0.50%
    Waveform 5 V p-p squarewave, -0.1 V offset
    RTDs and Thermocouples
    Measure and source accuracy Cu10 1.8°C
    NI-120 0.15°C
    PT-100 (385) 0.45°C
    PT-100 (392) 0.35°C
    PT-100 (391-JIS) 0.35°C
    PT-200 (385) 0.95°C
    PT-500 (385) 0.55°C
    PT-1000 (385) 0.35°C
    RTD Resolution 0.01°C (0.01°F)
    Cu10.01 C 0.1°C (0.1°F)
    J 0.4°C
    K 0.5°C
    T 0.4°C
    E 0.4°C
    R 1.4°C
    S 1.4°C
    B 1.4°C
    L 0.45°C
    U 0.45°C
    N 0.6°C
    XK 0.4°C
    BP 1.1°C
    TC Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
    Specifications
    Ramp functions Source functions Voltage, current, resistance, frequency, temperature
    Ramps Slow ramp, Fast ramp, 25% step-ramp
    Loop power function Voltage 24 V
    Accuracy 10%
    Maximum current 22 mA, short circuit protected
    Step functions Source functions Voltage, current, resistance, frequency, temperature
    Steps 25% of range, 100% of range
    Environmental Specifications
    Operating temperature -10°C to 55°C
    Storage temperature -20°C to 71°C
    Operating altitude 3000 m
    Safety Specifications
    Agency approvals EN 61010-1:1993, ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992
    Mechanical and General Specifications
    Size 200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in)
    Weight 650 g (23 oz)
    Batteries 4 AA alkaline batteries
    Battery replacement Separate battery compartment, accessible without breaking calibration seal
    Side port connections Pressure module connector, also used for remote real-time programming